1. FEATURES
Design according to EN ISO 13849-1 (Category 4、PLe);
Features of product: Relay output: 2 normally open contact, 1 normally close auxiliary contact;
Option:manual reset or automatic reset Self-check function redundant circuit design;
Self-protection when over-voltage or over-current;
Power supply anti-reverse connection protection design;
2. SPECIFICATIONS
Conformance standard | EN 60947-5-1,EN 61000-6-2,EN 61000-6-3,IEC/EN 60204-1,EN ISO 13849-1 | Control Level | EN954-1, the maximum safety control level 4 | Performance Level | ISO13849,Ple |
Power Voltage | 24VDC | Voltage Range | 85%~110% | Module Watts | 3 W |
Power and the Input Protection | Internal Self-recovery Fuse | State Display | Power/Channel 1/Channel 2 Three State LED Indicator Light | Start Button for Monitoring | Manual /Automatic |
Input | Dual Channel | Safety Output | Double output normally Open(13-14,23-24) | Signal Output | One output normally closed(31-32) |
Conventional Thermal Current Ith | 5A | The Insurance Level | 6A fast or 4A slow | Usage | AC-15,DC-13 |
Contact Resistance | ≤100mΩ | Mechanical Life | 10 million times | Operation Frequency | 6 time/minutes
|
Conformance standard | EN 60947-5-1,EN 61000-6-2,EN 61000-6-3,IEC/EN 60204-1,EN ISO 13849-1 | Control Level | EN954-1, the maximum safety control level 4 | Performance Level | ISO13849,Ple |
Power Voltage | 24VDC | Voltage Range | 85%~110% | Module Watts | 3 W |
Power and the Input Protection | Internal Self-recovery Fuse | State Display | Power/Channel 1/Channel 2 Three State LED Indicator Light | Start Button for Monitoring | Manual /Automatic |
Input | Dual Channel | Safety Output | Double output normally Open(13-14,23-24) | Signal Output | One output normally closed(31-32) |
Conventional Thermal Current Ith | 5A | The Insurance Level | 6A fast or 4A slow | Usage | AC-15,DC-13 |
Contact Resistance | ≤100mΩ | Mechanical Life | 10 million times | Operation Frequency | 6 time/minutes
|
3. WIRING
V+/VCC:Positive Pole ,connect to the DC24V
V-/GND:Negative Pole,connect to the DC0V
S1:The terminal of NPN signal input channel 1 for light curtain
S2:The termninal of NPN signal input channel 2 for light curtain
S33/S35:Manual start button
S33/S44:Automatic reset button
13/14,23/24:The terminal of dual safety output (NO)
31/32: The terminal of signal output (NC)
Power:Red LED, power (V+/V-)on
CH1:Green LED,light on when safety relay K1 closed
CH2:Green LED,light on when safety relay K2 closed
Reviews
There are no reviews yet.