NEW SELBER RB/RX RM-2305

  • Model: NEW SELBER RB/RX RM-2305
  • Maker: RIKEN KEIKI NARA
  • Introduces:
    High precision detection, resolution 0.1μm (max setting 99.9μm)Can be extended up to 8 channels (RX 1unit 2ch: RM-2505)Analog output function installed (Checks stripper plate waveform and detection timing position)
  • Download Product’s Catalog: 

    download RM-2305
    download RM-2305

Từ khóa sản phẩm:

, , , ,

Characteristics NEW SELBER RB/RX RM-2305

High precision detection, resolution 0.1μm (max setting 99.9μm)

Can be extended up to 8 channels (RX 1unit 2ch: RM-2505)

Analog output function installed (Checks stripper plate waveform and detection timing position)

Ideal for precision machining with evolution of first bound detection function (First bound peak value detection/First bound bottom peak variation detection)
PATENT NO. 6098979

* “RM-2305” is a model that combines one RM-2405 and one RM-2505.

.

NEW SELBER RB/RX RM-2305
NEW SELBER RB/RX RM-2305

Dạng Sóng

NEW SELBER RB/RX RM-2305
NEW SELBER RB/RX RM-2305
First bound waveform
NEW SELBER RB/RX RM-2305
NEW SELBER RB/RX RM-2305

Có thể kết hợp lên đến 4 bộ

NEW SELBER RB/RX RM-2305
NEW SELBER RB/RX RM-2305

Lắp phần này vào để kết nối

SPECIFICATIONS
Name NEW SELBER RB Base unit
Model RM-2405
Input 3 points, non-voltage NPN open collector output or contact input
Output 2 points, relay contact (C contact) NC-C-NO AC250V 2A Max. (Resistive load)
AC OUT 1A Max.
Maximum number of detection units installed RM-2505 4 units (8 channels)
Operating Temperature Limit 0-50℃ (No Condensation)
Ambient atmosphere when used Free from corrosive gas and dust
Power supply AC100V-240V 50/60Hz
Weight Main Unit: Approx. 1.4kg Mounting angle: Approx. 0.8kg
External Dimensions 150 (W) x 60 (H) x 140 (D) mm (excluding terminal block and other protrusions)
Name NEW SELBER RX Slug Detection Unit
Model RM-2505
Detection resolution 0.1μm (1μm when using RS-233H)
Monitoring method Previous value comparison
Maximum number of rotations that can be monitored 4000spm
Detection channel 1 unit 2 channels
External input (2 channels shared) 1 point, non-voltage NPN open collector output or contact input
External input Measurement waveform output (trace waveform/timing)
Operating Temperature Limit 0-50℃ (No Condensation)
Ambient atmosphere when used Free from corrosive gas and dust
Power supply Supplied from RM-2405
Weight Main Unit: Approx. 1kg
External Dimensions 150 (W) x 60 (H) x 140 (D) mm (excluding protrusions)

*The specifications and the contents described in this instruction manual are subject to change without prior notice.

.

Reviews

There are no reviews yet.

Be the first to review “NEW SELBER RB/RX RM-2305”

Your email address will not be published. Required fields are marked *