Riken Optech – Load Monitoring System PLA-2N

  • Model: ELV
  • Manufacturer: ESPE
  • Introduce:The PLA-2N has the function of detecting the press load with a strain gauge. It displays the accurate load during press processing, and output stop signals and stops a press machine immediately when abnormality is detected. Monitoring cannot be ignored when there are eccentric loads for each stroke, and furthermore, load monitoring extends the life of dies, prevents friction and wear of presses, also promotes quality control and rationalization.
  • Download catalogue: blank
Yêu Cầu Báo Giá Bộ Giám Sát Tải PLA-2N
Chọn Số Lượng Cho Sản Phẩm - Step 1 of 3

Từ khóa sản phẩm:

, , ,

Product Features
1.Easy to know the balance of loads applied to the left and right sides of the press, and to know improper balance, load center, etc., it facilitates die maintenance and quality control.
2.As a overload protector, it prevents from the damage of the dies by detecting double hits, mis-feed, change of material thickness etc., and estimates die regrinding intervals.
3.By knowing the suitable load for products, the selection of the press is facilitated.
4.The detector can be used to simultaneously set absolute value comparison (set value of upper/lower limits) and comparison with the value of the previous time.
5.The digital LED display is easy to read, and the bar display shows the left load and the right load in percentage.
Detecting Method
The PLA-2N has the function of detecting the press load with a strain gauge. It displays the accurate load during press processing, and output stop signals and stops a press machine immediately when abnormality is detected. Monitoring cannot be ignored when there are eccentric loads for each stroke, and furthermore, load monitoring extends the life of dies, prevents friction and wear of presses, also promotes quality control and rationalization.
blank
Description of Components
blank
1.Left Load Display
2.Left Bar Display
3.Total Load Display
4. Right Bar Display
5.Right Load Display
6.Waveform Output(Analog Signal
Output)
7.Right Sensitivity Control
8.Left Sensitivity Control
9.Power Switch
10.Display Change Key
11.Muting Key
12.Down Key(used to change settings)
13.Up Key(used to change settings)
14.Setting Key(used to change various settings)
15.Reset Key(pressing this key cancels the emergency condition)
16.Operation Lamp(lighting in red means thata fault signal is being output)
17.CAL Switch(to be pushed when viewing sensitivity settings)
18.Timing Lamp
Calibration

When the sensors are left as installed on and wires to the press, the tonnage indication is random and has no significance. Therefore, it is necessary to calibrate the amplification factor of the unit so as to indicate the accurate tonnage.

blank
KÍCH THƯỚT
blank
SPECIFICATIONS
Power Supply and Output section Power supply AC100~240V 50/60Hz
Power consumption 15W or less
Output contact 1A・1B(emergency stop output/auxiliary output)
Output contact capacity 250VAC or less, 5A or less Cosφ=1
Detection section No.of channels 2 channels
Detection range 100kN or more, available for press up to 40,000kN in capacity
Repeatability 0.5% of device press capacity
Sensor Strain gauge type 4-bridge strain sensor
Display section Display 1/2 inch 7-segment red LED, five-digit per channel
Others Backup With semiconductor memory, backup time:10 years or more
Maximum SPM 1,000 spm
Temperature range Working: -10°C-40°C(non freezing) / Storage: -20°C-55°C
Humidity range 10-85%RH (at wet bulb temperature of 229℃ or less, non condensation)

Reviews

There are no reviews yet.

Be the first to review “Riken Optech – Load Monitoring System PLA-2N”

Your email address will not be published. Required fields are marked *