Description
Malfunction detector PS-661 PS-662 is a malfunction-detecting device to monitor stamping processes, such as material end, miss-feeding and miss-ejection in automatic press stamping.
PS-662 inspects the processing by utilization of sensor input connected to PS-662 and the detection-timing signal which synchronizes with the operation of the press machine. When the malfunction is detected, a stop signal is output to the press machine.
The lot counter and the total counter are built in PS-662. The counter can control the number of products made by the press stamping.
Features
| The detection modes can be changed. Two detection modes are built in each detection channel. The combination of the detection modes is different in each channel. | |
| The sensor input polarity of each channel can be switched. | |
| All detection channels have the pin jack and the 3-contact jack. The contact type sensor is connected with the pin jack. The sensor (photo sensor and proximity sensor, etc.) which needs the power supply is connected with the 3-contact jack. | |
| The detection channel under use is displayed. The detection lamp illuminates green when the channel is in use. When a malfunction is detected, the detection lamp blinks red. | |
| The operation stop of the safety device is made easy to confirm. When the detection operation is stopped, some lamps are turned off. | |
| Large-scale figure LED is built in the counter display. The counter can be read from the remote place. | |
| Unnecessary operation can be excluded. When the operation inhibition input in the terminal block is turned on, other buttons than reset and monitor cannot be operated. |
Dimensions
PS-661

PS-662

Specification
| Specification | Detection channels | 6 |
| Detection timings | 3 input | |
| Power source for sensor | 12 V , 600 mA (max.) | |
| Detection style | 6 types (Touch, Synchronization, Extraction, Timer, Passage, Miss-feed) | |
| SPM | 1500 SPM (max.) | |
| Output | Emergency, T.D.C., alarm, continuous inhibition | |
| Relay output | 250 VAC / 30 VDC , 2A (max.) | |
| Input | Input Specification | Internal volt system (12 VDC) |
| H level | 9.0V or over, 1mA or below | |
| L level | 3.0V or below, 8mA or over (12mA MAX) | |
| Counter (PS-662) | Digits | 6 |
| Count speed | 1500 SPM (max.) | |
| Backup | 2 weeks | |
| Power source | Power supply voltage | AC100 ~ 240 V +/-10% 50/60Hz |
| Power consumption | 20 VA (max) | |
| Weight | Body 2.4 kg (PS-661), Body 2.5 kg (PS-662) (inc. mounting brackets.) | |
| Dimensions(WHD) | 200 * 98.5 * 184 mm (PS-661) 200 * 118.5 * 184 mm (PS-662) (An umbo is not included.) | |
| Ambient operating temperature | 0 to 55 degree C (No sudden temperature change during the use.) | |
| Ambient operating humidity | 35~85% RH (non condensing) | |
| Attachments | Output cable (Standard: 5 m) US-1 5 (blue, white, yellow, orange, pink) US-2 1 (red) Instruction manual |

Reviews