Malfunction Detector SD-101 SD-102 SD-201 SD-202 DUCIS

  • Model: Malfunction Detector SD-101/102/201/202
  • Maker: DUCIS
  • Introduces:
    + With 4 detection channels, it can be used alone or in combination
    + The interface is simple, clear, easy to understand and easy to operate
    + It has many modes for operation
    + Indicator light shows abnormality, reset button operation is easier
  • Tải Catalog sản phẩm: Malfunction Detector SD-101
Yêu Cầu Báo Giá Máy Dò Sự Cố SD-101/102/201/202
Step 1 of 2

Từ khóa sản phẩm:

, , , , ,

Malfunction Detector SD-101

Features
With 4 detection channels, it can be used alone or in combination
The interface is simple, clear, easy to understand and easy to operate
It has many modes for operation
Indicator light shows abnormality, reset button operation is easier
Very safe to use. Signal output, device shell are all passive electric shockproof, safer to use
sd-101 sd-102
“A” Corrugation Extrusion Detecting Rod: ”ON” Contact Check
“B” Feeding Out Detecting Rod: ”OFF” NON-Contact Check
“Synchro”
Shortage of feeding
Distance of feeding
Work with the feeding time of the machine to check feeding checking point is fixed at 90° .(TM yellow lamp).The material must be fed at right place before brightening of TM lamp. IF not, the machine stops.
“Memory” Discharging workpiece On every pressing stroke,it must has a workpiece to pass the detecting device(photoelectric,magnetic,micro,proximity switches,etc.)which outputs a checking signal to the controller to store(“MY”green lamp). TM lamp brightens and eliminates the memory if NO workpiece passes. The machine stops.
Detecting Device Proximity,photoelectric,infrared detection switch(DC 12V,built-in amplifier),and the detecting rod,micro-switches.
SD-101 SD-102
CH1-2 Check corrugation and extrusion of materials
(“A”position)check feeding out(“B”position).
CH1 Check corrugation and extrusion of materials
(“A”position)check feeding out(“B”position).
CH3 Check shortage of feeding, distance of feeding (“Synchro”position) using proximity switch, photoelectric switch. CH2 Check the orientation. Using the optical fiber.
CH4 Confirmation of discharging workpieces. Using SD-201/202. CH3 Check shortage of feeding, distance of feeding (“Synchro”position) using proximity switch, photoelectric switch.
CH4 Confirmation of discharging workpieces. Using SD-201/202.
Specifications
SD-101/102 SD-201/202
Channel 4.check individually Checking amplitude (Infrared detection)
SD-201:MAX 150mm
SD-202:MAX 100mm
Switches A/B,memory/synchronize Minimum check φ2mm(checking distance:0.5M) opacity
Response time “ON”check:3μ,”OFF”check:<300μ Checking distance <500mm
Power supply AC85V~250V、50/60Hz±10% Power supply DC12V(±10%)
Power consumption <16W Power consumption <60mA
Output signal Relay/A/B(220V3A),(110V8A) Indicating lamp Green:POWER , Red: GO
Delayed time <10ms Sensibility Adjusted by the shape of material and distance
Applicable temperature 0℃~40℃ Applicable temperature 0℃~40℃
Input signal DC12V、detecting device Response speed <1ms
Standard accessories SD-101:
Detecting rod 2pcs;proximity switch 1set;length of join cable 2pcs
SD-102:
Detecting rod 4pcs;proximity switch 1set;length of join cable 2pcs
Length of joint cable 2.5M
Dimensions 175W*212L*100H Dimensions 40W*210L*180H
Weight 2.65kg Weight Main unit:1.2kg/Reflective plate :0.3kg