Malfunction Detector SD-101
Features

| “A” Corrugation Extrusion | Detecting Rod: ”ON” Contact Check |
| “B” Feeding Out | Detecting Rod: ”OFF” NON-Contact Check |
| “Synchro” Shortage of feeding Distance of feeding | Work with the feeding time of the machine to check feeding checking point is fixed at 90° .(TM yellow lamp).The material must be fed at right place before brightening of TM lamp. IF not, the machine stops. |
| “Memory” Discharging workpiece | On every pressing stroke,it must has a workpiece to pass the detecting device(photoelectric,magnetic,micro,proximity switches,etc.)which outputs a checking signal to the controller to store(“MY”green lamp). TM lamp brightens and eliminates the memory if NO workpiece passes. The machine stops. |
| Detecting Device | Proximity,photoelectric,infrared detection switch(DC 12V,built-in amplifier),and the detecting rod,micro-switches. |
| SD-101 | SD-102 | ||
| CH1-2 | Check corrugation and extrusion of materials (“A”position)check feeding out(“B”position). | CH1 | Check corrugation and extrusion of materials (“A”position)check feeding out(“B”position). |
| CH3 | Check shortage of feeding, distance of feeding (“Synchro”position) using proximity switch, photoelectric switch. | CH2 | Check the orientation. Using the optical fiber. |
| CH4 | Confirmation of discharging workpieces. Using SD-201/202. | CH3 | Check shortage of feeding, distance of feeding (“Synchro”position) using proximity switch, photoelectric switch. |
| CH4 | Confirmation of discharging workpieces. Using SD-201/202. | ||
Specifications
| SD-101/102 | SD-201/202 | ||
| Channel | 4.check individually | Checking amplitude | (Infrared detection) SD-201:MAX 150mm SD-202:MAX 100mm |
| Switches | A/B,memory/synchronize | Minimum check | φ2mm(checking distance:0.5M) opacity |
| Response time | “ON”check:3μ,”OFF”check:<300μ | Checking distance | <500mm |
| Power supply | AC85V~250V、50/60Hz±10% | Power supply | DC12V(±10%) |
| Power consumption | <16W | Power consumption | <60mA |
| Output signal | Relay/A/B(220V3A),(110V8A) | Indicating lamp | Green:POWER , Red: GO |
| Delayed time | <10ms | Sensibility | Adjusted by the shape of material and distance |
| Applicable temperature | 0℃~40℃ | Applicable temperature | 0℃~40℃ |
| Input signal | DC12V、detecting device | Response speed | <1ms |
| Standard accessories | SD-101: Detecting rod 2pcs;proximity switch 1set;length of join cable 2pcs SD-102: Detecting rod 4pcs;proximity switch 1set;length of join cable 2pcs | Length of joint cable | 2.5M |
| Dimensions | 175W*212L*100H | Dimensions | 40W*210L*180H |
| Weight | 2.65kg | Weight | Main unit:1.2kg/Reflective plate :0.3kg |